Initially, when data is transmitted to the call logger via TCP/IP, the software differentiates its various sites by the sender's IP address, which is then used to assign a filename extension to each site. Thereafter, the data is being sent to the 

Referencemacro
Labelspool
folder for processing and will log in the system within the site whose filename extension it corresponds to.

...

Site 1 will send the data to TIM Professional, which will search for the IP address in the TCPSOURCES.CFG file and associate this with the extension MBG. A randomly named file is created in the

Referencemacro
Labelspool
folder containing the data sent from the telephone system, e.g.
Referencemacro
Label4de9380f.MBG

When the file is being picked up from the spool the 

Referencemacro
Labelspool
 folder, it can successfully be identified by the system as being sent from the
Referencemacro
LabelMain building
site, as described in the SITES.CFG file.

...