These instructions help you configure your Siemens OpenOffice phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Pbxsummary
RequiredTask4Configure TIM Plus
Supportfiles1Siemens OpenOffice.TDT
Supportfiles2Siemens.TDS
Supportfiles3Siemens.DBS
ConnectionDSN connection
RequiredTask1Configure the SMDR output
RequiredTask2Configure the interface file
RequiredTask3Set up a DSN connection
RequiredTask3Configure TIM Plus

HTML
<a id="Configure the SMDR output"></a>

...

By default, the SMDR output of a Siemens OpenOffice is not enabled. Contact your system maintainer to enable it for incoming, outgoing and internal calls.

 

HTML
<a id="Configure the interface file"></a>

Configure the interface file

 

Follow the steps below to configure the interface file to establish an HTTPS connection with your Siemens OpenOffice:

  1. Open the
    Referencemacro
    LabelSiemens OpenOffice.TDT
    file, located by default in
    Referencemacro
    LabelC:\Program Files (x86)\Tri-Line\TIM Enterprise\config
    .
  2. Edit the file to point to the IP address of your Siemens OpenOffice and enter the relevant username and password, as shown below.
    Screenshotmacro
    URL/download/attachments/3014664/siemens_openoffice_1.png
  3. Remove the apostrophe (') in front of the amended fields to enable them. An example of a configured interface file is shown below:
    Screenshotmacro
    URL/download/attachments/3014664/siemens_openoffice_4.png

 

 

HTML
<a id="Set up a DSN connection"></a>

...